Home Forums Community Extinguisher Requirement on Electrical Fork Lift

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • vickyp
    Keymaster
    Post count: 3644
    Forum: Community

    In Quebec, is there a regulatory requirement to ensure the presence of a fire extinguisher on/in an electrical fork lift or is it “simply” a Best practice’ What is the situation elsewhere in Canada’ Thank you!

    vickyp
    Keymaster
    Post count: 3644

    Not specifically required in an electric forklift but ARE specifically required in an ATV (OHS Regs):
    § 5. — All terrain vehicles
    286. Operating conditions: The use of an all-terrain vehicle is only permitted under the following conditions:
    (1) the vehicle is mounted on at least 4 wheels;
    (2) it is equipped with a portable fire extinguisher of the type ABC approved by Underwriters’ Laboratories of Canada (ULC), if the task involves any risk of fire;
    Here’s a quick rundown of some other jurisdictions:
    FED: Dry chem FE needed if forklift used to transport or handle \ flammable materials, (OHS Reg, Sec. 14.12)
    AB: Nothing specific
    BC: Powered Industrial Trucks (low lift and high lift) must meet ANSI Standard ANSI/ITSDF B56.1-2009, Safety Standard for Low Lift and High Lift Trucks(OHS Reg, Sec. 16&7)(d)) (Don’t know if standard requires FE but suspect it does)
    ON: Nothing specific
    Hope this helps and sorry for taking so long to reply.
    Glenn Demby, 203 354-4532

Viewing 2 posts - 1 through 2 (of 2 total)
  • You must be logged in to reply to this topic.